2,773 research outputs found

    Nationwide population-based cohort study of uterine rupture in Belgium : results from the Belgian Obstetric Surveillance System

    Get PDF
    Objectives: We aimed to assess the prevalence of uterine rupture in Belgium and to evaluate risk factors, management and outcomes for mother and child. Design: Nationwide population-based prospective cohort study. Setting: Emergency obstetric care. Participation of 97% of maternity units covering 98.6% of the deliveries in Belgium. Participants: All women with uterine rupture in Belgium between January 2012 and December 2013. 8 women were excluded because data collection forms were not returned. Results: Data on 90 cases of confirmed uterine rupture were obtained, of which 73 had a previous Caesarean section (CS), representing an estimated prevalence of 3.6 (95% CI 2.9 to 4.4) per 10000 deliveries overall and of 27 (95% CI 21 to 33) and 0.7 (95% CI 0.4 to 1.2) per 10000 deliveries in women with and without previous CS, respectively. Rupture occurred during trial of labour after caesarean section (TOLAC) in 57 women (81.4%, 95% CI 68% to 88%), with a high rate of augmented (38.5%) and induced (29.8%) labour. All patients who underwent induction of labour had an unfavourable cervix at start of induction (Bishop Score 7 in 100%). Other uterine surgery was reported in the history of 22 cases (24%, 95% CI 17% to 34%), including 1 case of myomectomy, 3 cases of salpingectomy and 2 cases of hysteroscopic resection of a uterine septum. 14 cases ruptured in the absence of labour (15.6%, 95% CI 9.5% to 24.7%). No mothers died; 8 required hysterectomy (8.9%, 95% CI 4.6% to 16.6%). There were 10 perinatal deaths (perinatal mortality rate 117/1000 births, 95% CI 60 to 203) and perinatal asphyxia was observed in 29 infants (34.5%, 95% CI 25.2% to 45.1%). Conclusions: The prevalence of uterine rupture in Belgium is similar to that in other Western countries. There is scope for improvement through the implementation of nationally adopted guidelines on TOLAC, to prevent use of unsafe procedures, and thereby reduce avoidable morbidity and mortality

    Local Hidden Variable Theories for Quantum States

    Get PDF
    While all bipartite pure entangled states violate some Bell inequality, the relationship between entanglement and non-locality for mixed quantum states is not well understood. We introduce a simple and efficient algorithmic approach for the problem of constructing local hidden variable theories for quantum states. The method is based on constructing a so-called symmetric quasi-extension of the quantum state that gives rise to a local hidden variable model with a certain number of settings for the observers Alice and Bob.Comment: 8 pages Revtex; v2 contains substantial changes, a strengthened main theorem and more reference

    Budget Feasible Mechanisms for Experimental Design

    Full text link
    In the classical experimental design setting, an experimenter E has access to a population of nn potential experiment subjects i{1,...,n}i\in \{1,...,n\}, each associated with a vector of features xiRdx_i\in R^d. Conducting an experiment with subject ii reveals an unknown value yiRy_i\in R to E. E typically assumes some hypothetical relationship between xix_i's and yiy_i's, e.g., yiβxiy_i \approx \beta x_i, and estimates β\beta from experiments, e.g., through linear regression. As a proxy for various practical constraints, E may select only a subset of subjects on which to conduct the experiment. We initiate the study of budgeted mechanisms for experimental design. In this setting, E has a budget BB. Each subject ii declares an associated cost ci>0c_i >0 to be part of the experiment, and must be paid at least her cost. In particular, the Experimental Design Problem (EDP) is to find a set SS of subjects for the experiment that maximizes V(S) = \log\det(I_d+\sum_{i\in S}x_i\T{x_i}) under the constraint iSciB\sum_{i\in S}c_i\leq B; our objective function corresponds to the information gain in parameter β\beta that is learned through linear regression methods, and is related to the so-called DD-optimality criterion. Further, the subjects are strategic and may lie about their costs. We present a deterministic, polynomial time, budget feasible mechanism scheme, that is approximately truthful and yields a constant factor approximation to EDP. In particular, for any small δ>0\delta > 0 and ϵ>0\epsilon > 0, we can construct a (12.98, ϵ\epsilon)-approximate mechanism that is δ\delta-truthful and runs in polynomial time in both nn and loglogBϵδ\log\log\frac{B}{\epsilon\delta}. We also establish that no truthful, budget-feasible algorithms is possible within a factor 2 approximation, and show how to generalize our approach to a wide class of learning problems, beyond linear regression

    NEMA NU 2-2007 performance characteristics of GE Signa integrated PET/MR for different PET isotopes

    Get PDF
    BackgroundFully integrated PET/MR systems are being used frequently in clinical research and routine. National Electrical Manufacturers Association (NEMA) characterization of these systems is generally done with F-18 which is clinically the most relevant PET isotope. However, other PET isotopes, such as Ga-68 and Y-90, are gaining clinical importance as they are of specific interest for oncological applications and for follow-up of Y-90-based radionuclide therapy. These isotopes have a complex decay scheme with a variety of prompt gammas in coincidence. Ga-68 and Y-90 have higher positron energy and, because of the larger positron range, there may be interference with the magnetic field of the MR compared to F-18. Therefore, it is relevant to determine the performance of PET/MR for these clinically relevant and commercially available isotopes.MethodsNEMA NU 2-2007 performance measurements were performed for characterizing the spatial resolution, sensitivity, image quality, and the accuracy of attenuation and scatter corrections for F-18, Ga-68, and Y-90. Scatter fraction and noise equivalent count rate (NECR) tests were performed using F-18 and Ga-68. All phantom data were acquired on the GE Signa integrated PET/MR system, installed in UZ Leuven, Belgium.Results(18)F, Ga-68, and Y-90 NEMA performance tests resulted in substantially different system characteristics. In comparison with F-18, the spatial resolution is about 1mm larger in the axial direction for Ga-68 and no significative effect was found for Y-90. The impact of this lower resolution is also visible in the recovery coefficients of the smallest spheres of Ga-68 in image quality measurements, where clearly lower values are obtained. For Y-90, the low number of counts leads to a large variability in the image quality measurements. The primary factor for the sensitivity change is the scale factor related to the positron emission fraction. There is also an impact on the peak NECR, which is lower for Ga-68 than for F-18 and appears at higher activities.ConclusionsThe system performance of GE Signa integrated PET/MR was substantially different, in terms of NEMA spatial resolution, image quality, and NECR for Ga-68 and Y-90 compared to F-18. But these differences are compensated by the PET/MR scanner technologies and reconstructions methods

    Suivi de la lixiviation du nitrate en plein champ par la technique lysimétrique : retour de huit années d'expérience

    Get PDF
    Monitoring of nitrate leaching in open fields by lysimeters: results from an eight year study. Since 2003, nitrate leaching has been monitored in six plots located in a loamy area (Hesbaye, Belgium), mainly dedicated to wheat, sugarbeet and vegetable crops. Open-field lysimeters have been used in order not to impede agricultural operations. Lysimeters are used as follow-up tools to quantify the amounts of nitrate leaching below the root zone. This study aims to evaluate the suitability of PLN (Potentially Leachable Nitrogen – APL in French) defined in the Sustainable Nitrogen Management Program (PGDA in French) as an environmental indicator by relating nitrogen management practices (including fertilization recommendations) to PLN values and groundwater quality. This study demonstrates that lysimeters are efficient in collecting representative amounts of leaching water. Lysimeters show that PLN is identified as being related to the nitrate content in leaching water, which will not be taken up by the next crop. The amount of nitrate leaching below the root zone demonstrates the necessity and the relevance of the organic nitrogen spreading limits defined in the Sustainable Nitrogen Management Program. The lysimeter tool also shows that respect for leaching water quality standards under agricultural plots needs to be considered from an integrated and generalized approach, taking into account complete crop sequences and rotations, including rational fertilization rates and the introduction of catch crops in rotation. Some suitable or unsuitable crop sequences with regard to good groundwater quality are listed

    Seizure onset zone localization from ictal high-density EEG in five patients

    Get PDF
    Rationale Because epilepsy is a network disease, localization of the exact seizure onset zone (SOZ) is difficult because the epileptic activity can spread to other regions within milliseconds. Functional connectivity metrics quantify how the activity in different brain regions is interrelated. In the past, it has been shown that functional connectivity analysis of ictal intracranial EEG (icEEG) recordings can help with SOZ localization in patients with focal epilepsy (van Mierlo et al., 2014). However, it would be of high clinical value to be able to localize the SOZ based on non-invasive ictal EEG recordings to optimize the icEEG implantation scheme or to avoid invasive monitoring and improve surgical outcome. In this work, we propose an approach to localize the SOZ based on non-invasive ictal high-density EEG (hd-EEG) recordings. Methods We considered retrospective ictal epochs of 2.4 s up to 10 s recorded with hd-EEG (256 electrodes) in five patients who were rendered seizure free after surgery. From the 256 electrodes, the facial electrodes were removed, resulting in a subset of 204 electrodes. A 28-channel subset was constructed to mimic a low-density (ld) electrode setup used in clinical practice. EEG source imaging (ESI) was performed in the CARTOOL software using an individual head model (LSMAC) to calculate the forward model (Brunet et al., 2011). We considered sources uniformly distributed in the brain with a spacing of 5 mm. LORETA (Pascal-Marqui et al., 1994) was used as inverse solution method. In each cluster of activity, we determined a central source based on the criterion that there was no higher power in its neighborhood. The time-varying connectivity pattern between the time series of these sources was calculated using Granger causality (van Mierlo et al., 2013). This was done in the frequency band containing the fundamental seizure frequency, 3-30Hz. The outdegree of each selected dipole was determined as the sum over time of all outgoing connections. Around the dipole with the highest outdegree, we determined a region of dipoles that had a power that was at least 90% of the power of the center dipole. This region was then considered as the SOZ. Results We were able to successfully localize the driver in the resected zone for all patients based on ESI followed by connectivity analysis of the hd-EEG (mean localization error (LE) = 0 mm). If we chose the cluster with the highest power as driver, the mean LE was 59.69 mm. For the ld-EEG, ESI followed by connectivity analysis resulted in a mean LE of 23.30 mm and when selecting the cluster with the highest power as driver, the mean LE was 31.21 mm. Conclusions ESI in combination with connectivity analysis can successfully localize the SOZ in non-invasive ictal hd-EEG recordings and greatly outperforms localization based on power. For ld-EEG recordings, the localization error remains significant but still outperforms localization based on power. This could have important clinical relevance for the presurgical evaluation in focal epilepsy

    Generalized phonon-assisted Zener tunneling in indirect semiconductors with non-uniform electric fields : a rigorous approach

    Full text link
    A general framework to calculate the Zener current in an indirect semiconductor with an externally applied potential is provided. Assuming a parabolic valence and conduction band dispersion, the semiconductor is in equilibrium in the presence of the external field as long as the electronphonon interaction is absent. The linear response to the electron-phonon interaction results in a non-equilibrium system. The Zener tunneling current is calculated from the number of electrons making the transition from valence to conduction band per unit time. A convenient expression based on the single particle spectral functions is provided, enabling the numerical calculation of the Zener current under any three-dimensional potential profile. For a one dimensional potential profile an analytical expression is obtained for the current in a bulk semiconductor, a semiconductor under uniform field and a semiconductor under a non-uniform field using the WKB (Wentzel-Kramers-Brillouin) approximation. The obtained results agree with the Kane result in the low field limit. A numerical example for abrupt p - n diodes with different doping concentrations is given, from which it can be seen that the uniform field model is a better approximation than the WKB model but a direct numerical treatment is required for low bias conditions.Comment: 29 pages, 7 figure

    Evaluation of resistive-plate-chamber-based TOF-PET applied to in-beam particle therapy monitoring

    Get PDF
    Particle therapy is a highly conformal radiotherapy technique which reduces the dose deposited to the surrounding normal tissues. In order to fully exploit its advantages, treatment monitoring is necessary to minimize uncertainties related to the dose delivery. Up to now, the only clinically feasible technique for the monitoring of therapeutic irradiation with particle beams is Positron Emission Tomography (PET). In this work we have compared a Resistive Plate Chamber (RPC)-based PET scanner with a scintillation-crystal-based PET scanner for this application. In general, the main advantages of the RPC-PET system are its excellent timing resolution, low cost, and the possibility of building large area systems. We simulated a partial-ring scannerbeam monitoring, which has an intrinsically low positron yield compared to diagnostic PET. In addition, for in-beam PET there is a further data loss due to the partial ring configuration. In order to improve the performance of the RPC-based scanner, an improved version of the RPC detector (modifying the thickness of the gas and glass layers), providing a larger sensitivity, has been simulated and compared with an axially extended version of the crystal-based device. The improved version of the RPC shows better performance than the prototype, but the extended version of the crystal-based PET outperforms all other options. based on an RPC prototype under construction within the Fondazione per Adroterapia Oncologica (TERA). For comparison with the crystal-based PET scanner we have chosen the geometry of a commercially available PET scanner, the Philips Gemini TF. The coincidence time resolution used in the simulations takes into account the current achievable values as well as expected improvements of both technologies. Several scenarios (including patient data) have been simulated to evaluate the performance of different scanners. Initial results have shown that the low sensitivity of the RPC hampers its application to hadro
    corecore